Asset ID: |
1-71-1349587.1 |
Update Date: | 2018-05-10 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1349587.1
:
How to Replace a Sun Fire X2270 M2 HDD and/or Filler
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X2270 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2270 M2 HDD and/or Filler.
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
- TIME ESTIMATE: 20 minutes
- TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: Removing and Installing a Hard Drive Filler and Hard Drive Assembly
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Then power down the system and disconnect the Power Cord.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1 For the drive slot in which you want to install a removable hard drive, rotate the release lever on the front of the filler to disengage the hook and extend the handle.
2 Use the handle to pull the filler out of the slot.
Remove
1 Power off the server. See How to Power Off the Server.
Note - If you are using an integrated-mirroring (IM) configuration, you do not need to power off the server before removing a hard drive, but you must ensure that the drive is disconnected from the OS and ready to be removed.
2 On the drive you want to remove, push the release button to open the latch and extend the latch to its fully-open position.
Note - The latch is not an ejector. Do not bend it too far to the right. Doing so may damage the latch.
3 To remove the drive, us the handle to pull the drive out of the drive slot.
4 If you are replacing the drive, go to How to Install a Removable Hard Drive Assembly.
5 If you are not replacing the drive, install a filler panel. See How to Install a Hard Drive Filler.
6 Power on the server. See How to Power On the Server.
Install
1 Power off the server. See How to Power Off the Server.
2 Ensure that the latch on the hard drive assembly is in the fully open position.
To open the latch, press the latch release button on the front of the assembly.
3 Slide the drive into the drive slot until it is fully seated and flush with the front of the server.
4 Close the latch.
5 Power on the server. See How to Power On the Server reconfigure the disk into the operating system and mirrored configuration.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE INFORMATION:
How to Remove a Hard Drive Filler
How to Install a Hard Drive Filler
How to Install a Removable Hard Drive Assembly
Sun Fire X2270 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19902-01/821-1345/
Detailed SVM instructions can be found at
http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html
See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions
References
<NOTE:1010946.1> - General Guidance for Diagnosis (Disk Failures/Errors) and Replacing Internal Server Disks and JBOD Disks within Solaris
<NOTE:1002753.1> - How to Replace a Drive in Solaris[TM] ZFS
Attachments
This solution has no attachment