How to Replace a Sun Fire X2270 M2 PCIe Card
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X2270 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2270 M2 PCIe Card.
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Then power down the system and disconnect the Power Cord.
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
REMOVING
1 Prepare the server for service. See How to Prepare for Service.
2 Remove the air duct. See How to Remove the Air Duct.
3 Disconnect any cables connected to the PCIe card.
4 To unlock the PCIe card, open the locking latch on the server rear panel.
5 To remove the PCIe card from the server, slide the card out of the server rear panel and disconnect the card from the PCIe riser.
6 Remove any card-specific cabling from the server.
7 Install the air duct. See How to Install the Air Duct.
8 Prepare the server for operation. See How to Prepare for Operation.
INSTALL
1 Prepare the server for service. See How to Prepare for Service.
2 Remove the air duct. See How to Remove the Air Duct.
3 If necessary, pull open the locking latch on the rear panel of the server to unlock the PCIe filler panel.
4 Remove the filler panel by lifting it straight up and out of the server.
5 If a PCIe riser is not already installed in the server, install a PCIe riser. See How to Install the PCIe Riser.
The PCIe riser is a low-profile, half-length x16 connector card.
6 Slide the new PCIe card into the PCIe slot on the rear panel of the server and connect the card to the PCIe riser.
7 To lock the PCIe card, push to close the locking latch on the rear panel of the server.
8 Attach any required internal cabling to the card.
9 Install the air duct. See How to Install the Air Duct.
10 Prepare the server for operation. See How to Prepare for Operation.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X2270 M2 Server Service Manual