How to Replace a Sun Fire X2200 M2 Cable Kit
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X2200 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2200 M2 Cable Kit.
Solution
CAP PROBLEM OVERVIEW: How to Remove and Replace Cable Kit
WHAT SKILLS DOES THE ENGINEER NEED?
ESD Awareness and basic hardware competence
Task Complexity: 0
Time Estimate: 30 minutes
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?
Power off the server and remove the top cover.
Lay out the replacement cable kit next to the installed cable kit to ensure the routing of the new cable kit matches that of the old cable kit.
Ensure that all connectors on the new kit match the connector name and location of the old cable kit.
Remove the old cable kit.
Install the new cable kit.
Replace the top cover.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM
TO AN OPERATIONAL STATE?
Power on the system
ANY PARTS NOTES?
371-2099 includes : Cable Kit
System Board J5 to I/O Board J1 Cable
Power Supply P3 to Disk Backplane 0 and 1 Cable
DVD Data/Power Cable
REFERENCE INFORMATION
See http://download.oracle.com/docs/cd/E19121-01/sf.x2200m2/819-6597-12/Chap4.html#0_78758