How to Replace a Sun Fire X2200 M2 Motherboard
Related Items |
- Sun Fire X2200 M2 Server
- Oracle Key Manager
- Sun StorageTek Crypto Key Management System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire X2200 M2 Server - Version Not Applicable and later
Oracle Key Manager - Version 1.1.0 and later
Sun StorageTek Crypto Key Management System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2200 M2 Motherboard.
Solution
CAP PROBLEM OVERVIEW: How to Remove and Replace Motherboard.
WHAT SKILLS DOES THE ENGINEER NEED?
X2200 M2 Trained.
Task Complexity: 3
Time Estimate: 90 minutes
5. WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?
o Power off the system and remove the cover
o Remove the PCIe card riser assembly installed on the motherboard
o Disconnect all cables attached to the motherboard.
o Remove the four screws from the heatsink (4 screws per heatsink installed).
Note: Do not remove the screws that secure the CPU heatsink assemblies mounting to the motherboard.
o Remove the seven Phillips screws that fasten the motherboard to the chassis with a Phillips screwdriver.
o Remove the screws attaching the serial connector to the chassis with a 5 mm nut driver.
o Pull the motherboard away from the chassis.
o Remove the CPU and memory modules.
To Install the Motherboard
o Center the motherboard on the chassis so that the screw holes in the motherboard align with the screw holes on the chassis.
o Secure the seven Phillips screws that fasten the motherboard to the chassis. Torque screws to 8- to 9-inch pounds.
o Secure the screws attaching the serial connector to the chassis with a 5 mm nut driver.
o Replace the CPU and DIMMs as necessary.
o Replace the PCIe card riser assembly and air baffle.
o Reconnect all internal system cables.
o Replace the system cover.
o Replace any external cables and power on the server.
NOTE: Please ensure that the platform or chassis serial number is correct - refer to How to update the Serial Number on Oracle x64 platforms (Doc ID 1364359.1)
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?
Power on the system
ANY PARTS NOTES?
REFERENCE INFORMATION
http://download.oracle.com/docs/cd/E19121-01/sf.x2200m2/819-6597-12/index.html