Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1347737.1
Update Date:2018-05-09
Keywords:

Solution Type  Technical Instruction Sure

Solution  1347737.1 :   How to Replace a Sun Fire X4170 M2 Light Pipe Assembly  


Related Items
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Qtr Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 One-Eighth Rack
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Full Rack
  •  
  • Exadata Database Machine X2-2 Half Rack
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Sun Fire X4170 M2 Server
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Half Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire X4170 M2 Server - Version Not Applicable and later
Exadata Database Machine X2-2 Hardware - Version All Versions and later
Exadata Database Machine X2-2 Qtr Rack - Version All Versions and later
Exadata Database Machine X2-2 Full Rack - Version All Versions and later
Exadata Database Machine X2-2 Half Rack - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4170 M2 Light Pipe Assembly.

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED: X4170 M2 Server Training
- TIME ESTIMATE: 60 minutes
- TASK COMPLEXITY: 3

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: Failed/Faulty Lightpipe
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
Customer should perform an orderly and graceful shutdown of applications and OS A data backup is not a pre-requisite but is a wise precaution.


Caution – Ensure that all power is removed from the server before removing or installing the light pipe assembly. You must disconnect the power cables before performing this procedure.

NOTE - 'If this is an Engineered system then the system administrator should prepare the system for service by performing any application related functions required to shutdown the node. This might include but is not limited to performing a system backup, failover of application or services, and finally a system shutdown.'

Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID: 1539451.1


- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
NOTE - You must remove the disk backplane to service the front control panel light pipe assemblies.

Prepare the server for service.

a. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
b. Remove the server from the rack.
c. Attach an antistatic wrist strap.
d. Remove the top cover.

Removing Light Pipe Assembly

1. Remove the storage drive cage.

2. Remove the disk backplane.

3. Remove the two No. 2 Phillips screws securing the front control panel light pipe assembly to the storage drive cage.

4. Remove the light pipe assembly from the storage drive cage.

Installing Light Pipe Assembly

1. Align the light pipe assembly with the mounting holes on the storage drive

2. Secure the light pipe assembly with the two No. 2 Phillips screws.

3. Install the disk backplane.

4. Install the storage drive cage.

5. Return the server to operation.

a. Install the top cover.

b. Install the server into the rack.
c. Return the server to the normal rack position.
d. Reconnect the power cord (or cords) to the power supply (or supplies) and power on the server.
Verify that the AC Present LED is lit.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Boot up system and verify full functionality

Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID: 1539451.1


PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170_M2/components.html

REFERENCE INFORMATION:

Sun Fire X4170 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19762-01/E22369-02/index.html

How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.