Asset ID: |
1-71-1347670.1 |
Update Date: | 2017-03-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347670.1
:
How to Remove and Replace V440/Netra 440 PCI Card:ATR:776:1 [Video]
Related Items |
- Sun Fire V440 Server
- Sun Netra 440 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Netra 440 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V440 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://mosemp.us.oracle.com and put a comment on Doc ID: 1347670.1
********************************************************************************
How to Remove and Replace a Sun Fire V440 Server PCI Card
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Nothing beyond basic hardware skills
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: Faulty PCI card.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD procedures to avoid Electrostatic Discharge
1. Ensure the server is powered off.
2. Ensure that the server is properly grounded.
3. Remove the cover.
4. Disconnect any external cables attached to the faceplate of the PCI card.
5. Disconnect any internal cables connected to the PCI card internal connectors.
6. Remove the Phillips No. 1 screw securing the card to the system back panel.
7. Pull the PCI card from its slot.
8. Insert the replacement PCI card into the appropriate slot on the motherboard.
9. Secure the PCI card faceplate to the system back panel with the Phillips No. 1 screw.
10. If necessary, connect any internal cables to the PCI card internal connectors.
11. If necessary, connect any external cables to the PCI card.
12. Refit the cover.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
Re-boot system and ensure that full PCI card functionality is achieved.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireV440/components.html
https://support.oracle.com/handbook_private/Systems/Netra_440_R/components.html
ADDITIONAL COMMENTS: V440 Server Parts Installation and Removal Guide 816-7729-10 and V440 Admin Guide 816-7728-10