Asset ID: |
1-71-1347663.1 |
Update Date: | 2017-03-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347663.1
:
How to Remove and Replace V440 Power Cord:ATR:772:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire V440 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Remove and Replace V440 Power Cord
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Nothing beyond basic hardware skills
TIME ESTIMATE: 15 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW:
Power Cord failed.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a prerequisite but is a wise precaution.
The customer is not required to perform a system shutdown.
The Sun Fire V440 server has dual redundant power supplies each with its own power cord. You can swap one power cord while the other one is still running.
For a single power source configuration, the system should be already powered down.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace the bad power cord.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
If the replacement was a hot swap on a redundant configuration, the system should be operational and need no further work.
If the replacement was in a system with a single power source, restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireV440/components.html#Cables
ADDITIONAL COMMENTS:
V440 Parts Installation & Removal Guide and Administration Guide
http://download.oracle.com/docs/cd/E19088-01/v440.srvr/index.html
Attachments