Asset ID: |
1-71-1347661.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347661.1
:
How to Remove and Replace V240 System Configuration Card
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Applies to:
Sun Fire V240 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Remove and Replace V240 System Configuration Card
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 15 minutes
TASK COMPLEXITY: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW:
Configuration Card Failed
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTIONS ARE REQUIRED:
Ensure that the system configuration card is not removed before system is brought down.
Follow standard ESD procedures to avoid Electrostatic Discharge
Replace the part following the steps below, reference the service manual below:
Remove the defective part:
1.Power off the server.
2.Ensure that the server is properly grounded.
3.Remove the front section of the cover assembly.
4.Remove the system configuration card.
Install the new part:
1.Install the system configuration card.
2. Replace the front cover assembly section
3. Power on the server.
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireV240/components.html#Card/Reader
https://support.oracle.com/handbook_private/Systems/SunFireV240_R/components.html#Card/Reader
REFERENCE INFORMATION:
Service Manual 819-4207-10 and Admin Guide 819-4208-10
http://download.oracle.com/docs/cd/E19088-01/v240.srvr/index.html
Attachments
This solution has no attachment