Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1347660.1
Update Date:2018-05-09
Keywords:

Solution Type  Technical Instruction Sure

Solution  1347660.1 :   How to Replace a Sun Fire X4170 M2 Power Distribution Board Ribbon Cable  


Related Items
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Qtr Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 One-Eighth Rack
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Full Rack
  •  
  • Exadata Database Machine X2-2 Half Rack
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Sun Fire X4170 M2 Server
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Half Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire X4170 M2 Server - Version Not Applicable and later
Exadata Database Machine X2-2 Hardware - Version All Versions and later
Exadata Database Machine X2-2 Qtr Rack - Version All Versions and later
Exadata Database Machine X2-2 Half Rack - Version All Versions and later
Exadata Database Machine X2-2 Full Rack - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4170 M2 Power Distribution Board Ribbon Cable.

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED: General Sun X64 Servers Knowledge
- TIME ESTIMATE: 60 minutes
- TASK COMPLEXITY: 1

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: Replacement Power Distribution Board Cable
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID: 1539451.1

NOTE - 'If this is an Engineered system then the system administrator should prepare the system for service by performing any application related functions required to shutdown the node. This might include but is not limited to performing a system backup, failover of application or services, and finally a system shutdown.'


Prepare the server for service.
a. Power off the server and disconnect the power cord/s from the power supply/s.
b. Extend the server to the maintenance position.
c. Attach an antistatic wrist strap.
d. Remove the top cover.

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removing.

Remove the existing power distribution board cable. The power distribution board cable connects between the power distribution
board and the motherboard.
a. Release the latches on both sides of the cable connector on the power distribution board and pull the cable straight up .
b. Release the latches on both sides of the cable connector on the motherboard and pull the cable straight up.

Installing

Install Power Distribution Board Cable. The power distribution board cable connects between the power distribution board and the motherboard.
1. Install the power distribution board cable.
a. Ensure that the latches on the power distribution board connector are in the open position and connect ribbon cable to the connector.
Ensure that the ribbon cable connector is seated properly.
b. Ensure that the latches on the motherboard connector are in the open position and connect ribbon cable to the connector.
Ensure that the ribbon cable connector is seated properly.
2. Return the server to operation.
a. Install the top cover.
b. Return the server to the normal rack position.
c. Reconnect the power cord (or cords) to the power supply (or supplies) and power on the server.
Verify that the AC Present LED is lit.

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Restart the server and check all devices are working.

Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID: 1539451.1


PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170_M2/components.html

REFERENCE INFORMATION:

Sun Fire X4170 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19762-01/E22369-02/index.html