Goal

How to Remove and Replace V240 U/L Interface Board

Solution

*DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

V240 product knowledge/training to be qualified as Oracle service personel.

TIME ESTIMATE: 50 minutes

TASK COMPLEXITY: 1

*FIELD ENGINEER INSTRUCTIONS*

PROBLEM OVERVIEW:
Failed interface board.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Power down system.


WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Take appropriate ESD precautions and ensure that system is powered down.

2. Remove cover assembly.

3. Remove all hard drives, noting their positions for re-installation.

4. Disconnect interface board interconnect cable.

5. Disconnect PDB cable.

6. Unscrew the seven screws that secure the upper interface board.

7. Lift the upper interface board out of the chassis.

On the lower interface board:.

8. Disconnect the system board cable.

9. Disconnect the PSU cable.

10. Disconnect system configuration card reader cable.

11. Unscrew the three screws and five standoffs that secure the lower interface board to the chassis.

12. Lift board partway from chassis and remove cable from bezel assembly.

13. Remove lower interface board from chassis.

14. Locate the new lower interface board into the chassis using the screw hole in the corners as guides.

15. Screw the lower interface board into place.

16. Attach bezel, PCB, PSU and system board cables.

17. Locate the upper interface board using the shoulder standoffs as guides.

18. Screw the upper interface board into place.

20. Attach lower interface board, PDB and system board connection cables.

21. Reinstall disk drives in their respective slots.

22. Reinstall cover assembly.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot Operating system and start applications.

PARTS NOTE:
https://support.oracle.com/handbook_partner/Systems/SunFireV240/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV240_R/components.html



REFERENCE INFORMATION:
Service Manual 819-4207-10 and Admin Guide 819-4208-10