Asset ID: |
1-71-1347621.1 |
Update Date: | 2018-05-23 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347621.1
:
How to Replace a Sun Fire X4170, X4270 Compact Flash
Related Items |
- Sun Fire X4270 Server
- Sun Fire X4170 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4270 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire X4170 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4170, X4270 Compact Flash.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4170, X4270 Compact Flash needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Then power down the system and disconnect the Power Cord.
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:faulty compact flash
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Powering off the system and disconnect the power cords from the system
2. Remove the top cover
3. Remove the PCIe Riser in slot 0
4. Remove the compact flash
5. Install new compact flash
6. Install the PCIe Riser into Slot0
7. Install the top cover
8. Connect the power cords and power on the system
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170/components.html
https://support.oracle.com/handbook_private/Systems/SunFireX4270/components.html
REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19477-01/820-5830-13/index.html
Attachments
This solution has no attachment