  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun Virtual Library Extension (VLE) - Version: 1.0 and later   [Release: 1.0 and later ]
Information in this document applies to any platform.

Goal

How to Remove and Replace VLE Server Controller

Solution

CAP PROBLEM OVERVIEW: Servicing Array Controller

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Trained on J4400 & VLE

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 2

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Take ESD Precautions

CAUTION: Although replacement of a SIM card is not disruptive, upgrading the firmware is disruptive.
If the new SIM card is found to have down level firmware you will need to schedule a disruptive
outage to upgrade the SIM card firmware.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Potential loss of data access: Never remove a SIM board unless the SIM Locate LED is blue

Remove SIM Board

From the back of the disk tray, locate the failed SIM. The SIM Locate LED is blue
Label and then disconnect the tray interface cables ( Use two hands to disconnect the SAS cable. Grasp the metal body of the connector with one hand and firmly grasp and pull the tab gently toward the connector body with the other, then pull the connector body outward to extract it from the bulkhead.)
Loosen the two extraction arm captive screws using your thumb and forefinger
Pull each ejector tab outward and push to the sides to release and partially eject the SIM from the chassis
Grasp the middle of the SIM board and slide it out of the slot
Replace

Pull the ejector arms to the full open position
Align the new SIM board with the open slot and slide it into the tray until the ejector arms contact the tray connectors and begin to swing closed
Simultaneously swing both ejector arms in until they are flush with the SIM board panel to seat the board
Tighten both captive screws to secure the board
Reconnect the tray interface cables to their original locations
Verify

Wait approximately 60 seconds for the SIM board to complete its boot process, at which point ensure that the following is true:
The Power LED is solid green
The SIM Locate LED is off
OBTAIN CUSTOMER ACCEPTANCE