Asset ID: |
1-71-1347545.1 |
Update Date: | 2018-05-09 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347545.1
:
How to Replace a Sun Fire X4170 M2 DVD/USB Module
Related Items |
- Exadata Database Machine X2-2 Qtr Rack
- Oracle Exalogic Elastic Cloud X2-2 Qtr Rack
- Oracle Exalogic Elastic Cloud X2-2 One-Eighth Rack
- Exadata Database Machine X2-2 Full Rack
- Oracle Exalogic Elastic Cloud X2-2 Full Rack
- Exadata Database Machine X2-2 Half Rack
- Exadata Database Machine X2-2 Hardware
- Sun Fire X4170 M2 Server
- Oracle Exalogic Elastic Cloud X2-2 Hardware
- Oracle Exalogic Elastic Cloud X2-2 Half Rack
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire X4170 M2 Server - Version Not Applicable and later
Exadata Database Machine X2-2 Hardware - Version All Versions and later
Exadata Database Machine X2-2 Qtr Rack - Version All Versions and later
Exadata Database Machine X2-2 Half Rack - Version All Versions and later
Exadata Database Machine X2-2 Full Rack - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4170 M2 DVD/USB Module.
Solution
(Note, if the x86 server is part of an Engineered System, there is no DVD. In that case, this document would only pertain to the USB device on the x86 server).
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
General Sun X64 Servers Knowledge
- TIME ESTIMATE: 60 minutes
- TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS
- PROBLEM OVERVIEW: DVD/USB module Replacement
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID:
1539451.1
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removing DVD/USB Module
1. Remove media from the drive.
2. Power off the server.
3. Attach an antistatic wrist strap.
4. Remove the server storage drive located below and to the right the DVD/USB module.
Note: No screwdriver required
If you don't see the magic release at first, remove the HDD or blank in slot 7,
and look in between the disk and the optical drive.
5. Release the DVD/USB module from the disk backplane. Grasp the release tab under the DVD/USB module and pull it out to release the module from the disk backplane.
6. Slide the DVD/USB module out of the storage drive cage.
7. Place the module on an antistatic mat.
Installing DVD/USB Module
1. Push the DVD/USB module release tab back into the system.
2. Slide the DVD/USB module into the storage drive cage until it seats.
3. Install the storage drive you removed during the DVD/USB module removal procedure.
4. Power on the server.
Verify that the Power/OK LED is lit.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify functionality of device
Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID:
1539451.1
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4170 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19762-01/E22369-02/index.html
How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1)
Attachments