Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1347544.1
Update Date:2018-05-09
Keywords:

Solution Type  Technical Instruction Sure

Solution  1347544.1 :   How to Replace a Sun Fire X4170 M2 Coin Cell Battery  


Related Items
  • Oracle Exalogic Elastic Cloud X2-2 Qtr Rack
  •  
  • Sun Fire X4170 M2 Server
  •  
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 One-Eighth Rack
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Full Rack
  •  
  • Exadata Database Machine X2-2 Half Rack
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Half Rack
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Applies to:

Oracle Exalogic Elastic Cloud X2-2 One-Eighth Rack - Version X2 and later
Oracle Exalogic Elastic Cloud X2-2 Qtr Rack - Version X2 and later
Exadata Database Machine X2-2 Full Rack - Version All Versions and later
Sun Fire X4170 M2 Server - Version All Versions and later
Exadata Database Machine X2-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4170 M2 Coin Cell Battery.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
General Sun X64 Servers Knowledge
TIME ESTIMATE: 30 minutes

FIELD ENGINEER INSTRUCTIONS
- PROBLEM OVERVIEW: System Board Battery Replacement
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID: 1539451.1

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Prepare the server for service.
a. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
b. Remove the server from the rack.
c. Attach an antistatic wrist strap.
d. Remove the top cover.

Removing the battery.

a. Place you finger between the battery and sidewall of the server chassis and push the battery away from the sidewall.
b. Twist the battery (either clockwise or counter-clockwise) and lift it out.

Installing Battery.

1. Unpack the replacement battery.
2. Press the new battery into the battery holder with the positive side (+) facing the server chassis sidewall.
3. If the service processor is configured to synchronize with a network time server using the Network Time Protocol (NTP), the ILOM clock will be reset as soon as the server is powered on and connected to the network. Otherwise, proceed to the next step.
4. If the service processor is not configured to use NTP, you must reset the ILOM clock using the ILOM CLI or the web interface.
5. Return the server to operation.
a. Install the top cover.
b. Return the server to the normal rack position.
c. Reconnect the power cord (or cords) to the power supply (or supplies) and power on the server.
Verify that the AC Present LED is lit.

OBTAIN CUSTOMER ACCEPTANCE

- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Check for full system functionality

Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID: 1539451.1


PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170_M2/components.html#SystemBoard

REFERENCE INFORMATION:

Sun Fire X4170 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19762-01/E22369-02/index.html

How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback