Asset ID: |
1-71-1347329.1 |
Update Date: | 2018-05-24 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347329.1
:
How to Replace a Sun Fire X4170, X4270 CPU Heatsink
Related Items |
- Sun Fire X4270 Server
- Sun Fire X4170 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: fru cap
Applies to:
Sun Fire X4170 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire X4270 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4170, X4270 CPU Heatsink.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4170, X4270 Training
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 3
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4170, X4270 CPU Heatsink needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Then power down the system and disconnect the Power Cord.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Unscrew the two Phillips head screws from the heatsink
Turn the screws alternately one and one half turns until they are fully removed.
2. Twist the heatsink slightly to break the grease seal, lift off the heatsink and
place it upside down on a flat surface to prevent the thermal grease from
contaminating other components.
3. Use an alcohol pad to clean the thermal grease from both the bottom of the
heatsink and the top of the CPU
Be very careful not to get the thermal grease on your fingers as this could result in
contamination of components.
4. Use the syringe (supplied with the new or replacement CPU) to apply
approximately 0.1 ml of thermal grease to the center of the top of the CPU.
Do not distribute the grease.
5. Inspect the heatsink for dust and lint. Clean if necessary.
6. Orient the heatsink so that the two screws line up with the mounting studs
7. Carefully position the heatsink on the CPU, aligning it with the mounting
posts to reduce movement after it makes initial contact with the layer of
thermal grease
Caution ! If the heatsink assembly is moved too much during its installation, the
layer of thermal grease may not be distributed evenly, leading to component damage.
8. Tighten the screws alternately one-half turn until fully seated.
9. Re-fit cover
10. Power on
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Check for full system functionality
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19477-01/820-5830-13/index.html
Attachments
This solution has no attachment