Goal
Solution


Applies to:

Sun Fire X4170 Server - Version All Versions and later
Sun Fire X4270 Server - Version All Versions and later
Sun Fire X4275 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4170, X4270, X4275 Internal RAID HBA BBU.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4170, X4270, X4275 Internal RAID HBA BBU needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Then power down the system and disconnect the Power Cord.

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Powering off the system and disconnect the power cords from the system

2. Remove the top cover

3. Remove the PCI Riser

4. Remove SAS HBA and place the card on an antistatic mat

5. Replace the battery module on the card with spare battery module

6. Install SAS HBA into the system

7. Install the PCI Riser

8. Install the top cover

9. Connect the power cords and power on the system

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:

PARTS NOTE:

https://support.oracle.com/handbook_private/Systems/SunFireX4170/components.html
https://support.oracle.com/handbook_private/Systems/SunFireX4270/components.html
https://support.oracle.com/handbook_private/Systems/SunFireX4275/components.html



REFERENCE INFORMATION:

Sun Fire X4170, X4270, and X4275 Servers Service Manual located at http://docs.oracle.com/cd/E19477-01/820-5830-13/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback