Asset ID: |
1-71-1347161.1 |
Update Date: | 2017-03-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347161.1
:
How to Remove and Replace a Netra 440 Power Cord:ATR:1836:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Netra 440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a Netra 440 Power Cord
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Nothing beyond basic hardware skills
- TIME ESTIMATE: 15 minutes
- TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW: Power Cord failed.
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
A data backup is not a pre-requisite but is a wise precaution.
The customer is not required to perform a system shutdown.
The Netra 440 has up to 4 PSUs with either AC or DC inputs. A minimum of two PSUs are required for normal operation.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace the bad power cord.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
If the replacement was a hot swap on a redundant configuration, the system should be operational and need no further work.
If the replacement was in a system with a single power source, restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
Refer to the System Handbook for the country specific type of power cord.
https://support.oracle.com/handbook_private/Systems/Netra_440/components.html#Cables
REFERENCE INFORMATION:
Netra 440 Service Manual
Netra 440 System Admin Guide
Attachments
This solution has no attachment