How to Replace a Sun Fire X2200 M2 Single Fan
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X2200 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2200 M2 Single Fan.
Solution
CAP PROBLEM OVERVIEW: How to Remove and Replace Single Fans
WHAT SKILLS DOES THE ENGINEER NEED?
ESD Awareness and basic hardware competence
Task Complexity: 0
Time Estimate: 90 minutes
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?
Power off the system and remove the cover
Identify the fan to be replaced.
Pull the fan upward to remove it.
Unplug the fans power connector from the connector on the fan harness.
To Install a Fan Module
Position the fan so that the arrow on top of the fan casing is facing the middle chassis divider.
Place the fan in the chassis so that it fits over the small guideposts.
Gently push the fan down to secure it to the chassis.
Connect the fan connector to the appropriate connector on the fan harness.
Check the routing of all cables for obstructions, and then reinstall the cover.
6. WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM
TO AN OPERATIONAL STATE?
Power on the system.