  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun Ultra 27 Workstation - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Information in this document applies to any platform.

Goal

How to Replace a Sun Ultra 27 Workstation Fan

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner.

TIME ESTIMATE: 60 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software and system shutdown.
System power off is required.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Power off the workstation.

2. Remove the left-side access panel.

3. Locate the systemfan on the back inside panel of theworkstation.

4. Disconnect the systemfan’s power connector fromthe SYS_FAN connector on the motherboard.

5. Release the fan’s power cord fromthe cable management strap.

6. On the interior back panel of theworkstation, lift the two fan bracket chassis retaining clips.

7. Slide the fan assembly downto release the four hooks on the back of the bracket fromthe holes in the chassis.

8. Remove the fan fromthe chassis and note the orientation of the fan in the mounting bracket.

9. Remove the fan fromthe chassis and note the orientation of the fan in the mounting bracket.

10. To install the new fan in the mounting bracket, position the fan over the bracket with the protective grill facing away fromthe bracket and the fan power cable positioned near the two chassis retaining clips.

11. Line up the four corner pins in the bracket with the holes in the corners of the fan.

12. Press the fan into the bracket.

13. Position the fan assembly against the interior chassis back panel with the four hooks on the fan bracket aligned with the four mounting holes.

14. Press the fan against the back panel and slide the fan upward until the chassis retaining clips click into their locked position.

15. Route the fan’s power cord through the cable management strap near the top right corner of the motherboard.

16. Connect the fan cable to the SYS_FAN connector on the motherboard.

17. Close theworkstation and prepare for operation.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

See Page 69 (Sun Ultra 27 Workstation Service Manual)