Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1337144.1
Update Date:2018-05-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1337144.1 :   How to Replace a Sun Fire X2100 M2 PCIe Riser Card  


Related Items
  • Sun Fire X2100 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
 Powering Off the server and Removing the Cover.
 Removing the Riser Assembly and PCIe Card
 Installing the PCIe Card and Riser Card Assembly


Applies to:

Sun Fire X2100 M2 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X2100 M2 PCIe Riser Card.

Solution

1. CAP PROBLEM OVERVIEW:
    How to Remove and Replace a X2100 M2 PCI Express Riser

2. WHAT SKILLS DOES THE ENGINEER NEED?
    Nothing beyond basic hardware and Solaris training

3. Task Complexity: 0 = CRU

4. Time Estimate: 60 minutes

5. WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?

Powering Off the server and Removing the Cover.

  I. If the operating system (OS) is running, perform a shutdown of the OS, and then press and release the  platform power button on the front panel.
 II. Turn off all peripheral devices connected to the system.
III. Disconnect the AC power on the back panel of the server.
IV. Label and disconnect all peripheral cables and all telecommunication lines connected to I/O connectors or ports on the back panel of the system.
V. Before handling components, attach a wrist strap to a chassis ground (any unpainted metal surface).
VI. Loosen the two captive screws securing the cover to the chassis
VII. Pull the cover slightly toward the back of the server and then straight up to remove it.
VIII. Lift the cover and remove it.

Removing the Riser Assembly and PCIe Card

 I. Placing your fingers on the two green areas on the riser card, pull the assembly upward and out of the chassis.
II. Unlatch the PCIe card and remove the card from the PCIe card riser assembly connector.

Installing the PCIe Card and Riser Card Assembly

I. If necessary, remove the riser card filler panel.
II. Connect the new PCIe in the riser assembly and fasten the latch to secure it.

7. WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM
TO AN OPERATIONAL STATE?
Verify the proper device operation

8. ANY PARTS NOTES?
1-Slot PCI Express Riser
2-Slot PCI Express Riser

REFERENCE INFORMATION

Sun Fire X2100 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x2100m2/819-6591-11/


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback