How to Replace a Sun Fire X2250 Removable Media Assembly
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X2250 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2250 Removable Media Assembly.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner.
TIME ESTIMATE: 60 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software and system shutdown.
System power off is required.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the system and remove the cover.
2. Unfasten the drive ribbon cable from the ODD drive.
3. Push the latch on the back of the ODD drive toward the drive until the ODD drive springs forward out of the chassis.
4. Pull the ODD drive out the front of the chassis.
5. If necessary, remove the filler panel in front of the ODD drive slot on the front panel.
6. Position the ODD drive in front of the ODD drive slot on the front panel.
7. Push the ODD drive into the drive slot until the drive clicks into place.
8. Reinstall the ODD drive cable.
9. Check the routing of all cables for obstructions, and then reinstall the cover.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
See chapter 4.5.5 Removing and Installing the ODD Drive Assembly (Sun Fire X2250 Server Service Manual)
REFERENCE:
Sun Fire X2250 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x2250/820-4593-12/
Attachments