Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1336559.1
Update Date:2018-05-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1336559.1 :   How to Replace a Sun Fire X2250 Motherboard  


Related Items
  • Sun Fire X2250 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire X2250 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X2250 Motherboard.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner.

TIME ESTIMATE: 60 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software and system shutdown.
System power off is required.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Power off the system and remove the cover.

2. Remove the PCIe card riser assembly installed on the motherboard.

3. Disconnect all cables attached to the motherboard.

4. Remove the four screws from the heatsink (4 screws per heatsink installed).

5. Using a Phillips screwdriver, remove the seven Phillips screws that fasten the motherboard to the chassis.

6. Using a 5-mm nut driver, remove the screws attaching the serial connector to the chassis.

7. Pull the motherboard away from the chassis.

8. Remove the CPU and memory modules.

9. Center the motherboard on the chassis so that the screw holes in the motherboard align with the screw holes on the chassis.

11. Secure the seven Phillips screws that fasten the motherboard to the chassis. Torque screws to 8-9 inch-pounds.

12. Using a 5-mm nut driver, secure the screws attaching the serial connector to the chassis.

13. Replace the CPU and DIMMs as necessary.

14. Replace the PCIe card riser assembly and air duct.

15. Reconnect all internal system cables.

16. Replace the system cover.

17. Replace any external cables and power on the server.


OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Apply power to the system.
Once the ILOM is booted, log in.
Start the console and monitor the POST and boot process to ensure that the replacement process has been successful.

See chapter 4.5.15 Motherboard (Sun Fire X2250 Server Service Manual)

REFERENCE:
Sun Fire X2250 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x2250/820-4593-12/