Asset ID: |
1-71-1336535.1 |
Update Date: | 2018-05-10 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1336535.1
:
How to Replace a Sun Fire X2250 Memory DIMM
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X2250 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2250 Memory DIMM.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner.
TIME ESTIMATE: 60 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software and system shutdown.
System power off is required.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the system and remove the cover.
2. Locate the DIMM connector in which you will install or replace a memory module.
3. Remove a DIMM by pressing down on the ejector levers at both ends of the memory modules socket
4. Pull the DIMM up and out of the socket.
5. Ensure that the DIMM socket ejector levers are open (rotated outward) to allow the new module to be inserted.
6. Align the DIMMs edge connector with the alignment key and insert the memory module into the connector.
7. Using both thumbs, press the DIMM straight down into the DIMM slot until both ejector levers click, locking the DIMM in the DIMM slot.
8. Check the routing of all cables for obstructions, and then reinstall the cover.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Apply power to the system.
Once the ILOM is booted, log in.
Start the console and monitor the POST and boot process to ensure that the replacement process has been successful.
See chapter 4.5.10 Replacing Memory Modules (Sun Fire X2250 Server Service Manual)
REFERENCE:
Sun Fire X2250 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x2250/820-4593-12/
Attachments
This solution has no attachment