How to Replace a Sun Fire X2250 PCIe Riser and/or PCIe Card
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X2250 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2250 PCIe Riser and/or PCIe Card.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
ESD Awareness and basic hardware competence.
TIME ESTIMATE: 60 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software and system shutdown.
System power off is required.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the system and remove the cover
2. Placing your fingers on the two green areas on the riser assembly, pull the assembly upward and out of the chassis.
3. Unlatch the PCIe card and remove the card from the PCIe card riser assembly connector.
4. If necessary, remove the riser card filler panel.
5. Insert the new PCIe card into the riser assembly and fasten the latch to secure the card.
6. Reinstall the riser assembly into the connector on the motherboard.
7. Check the routing of all cables for obstructions, and then reinstall the cover.
8. Boot the system and check that the PCIe card is accessible by the OS.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
See chapter 4.5.2 Replacing the PCIe Card and Riser Assembly (Sun Fire X2250 Server Service Manual)
REFERENCE:
Sun Fire X2250 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x2250/820-4593-12/