Goal
How to Remove / Replace Library Controller Card From SL48 Tape Library:ATR:1336130.1:0 (Doc ID 1336130.1)
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Knowledge on SL48 Library.
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
Library should be offline to the Server and software application.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Refer to the SL48 Service Manual for additional information on the following actions.
http://download.oracle.com/docs/cd/E19947-01/875-4225-10/875-4225-10.pdf
Replacing the library controller (SL48)
This process applies to the SL48 only. In this process you will:
• Record the Library settings.
• Power off the Library, unplug the power cord, and remove the Ethernet cable.
• Remove the old library controller.
• Install the new library controller.
• Verify the replacement.
CAUTION:
Parts can be damaged by electrostatic discharge. Keep parts in electrostatic containers until needed. Ensure that you are properly grounded when touching static‐sensitive components.
CAUTION:
This part is not hot‐pluggable. You must power down the Library to replace the library controller.
To replace the library controller:
1. Record the Libraryʹs settings by writing down the values displayed in the OCP or the RMI.
2. Power off the Library from the front panel. Remove the Ethernet cable, if applicable.
3. Loosen the two captive thumbscrews on the library controller and remove it from the Library, as shown in Figure 104).
4. Position the new library controller on the alignment rails and slide it into the Library until it is flush with the back panel, as shown in Figure 105. Tighten the two blue thumbscrews to secure the card to the Library.
5. Replace the Ethernet cable, if applicable. Power on the Tape Library.
6. Confirm that the Library recognized the new library controller by checking the System Status on the front panel, as shown in Figure 106.
7. Restore the previous settings by manually entering them in the OCP or RMI.
8. If necessary, upgrade the Library and drive firmware using the RMI or a USB flash drive.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Bring library back online to the server and software application. Verify library is recognized by application.
PARTS NOTE:
Sun StorageTek SL48 Tape Library, RoHS:YL - Full Components List
https://support.us.oracle.com/handbook_internal/Systems/SL48/components.html
REFERENCE INFORMATION:
SL48 Service Manual
http://download.oracle.com/docs/cd/E19947-01/875-4225-10/875-4225-10.pdf