![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1335086.1 : How to Replace a SPARC T3-2 DVD Drives:ATR:1335086.1:0
In this Document
Applies to:SPARC T3-2 - Version Not Applicable and laterInformation in this document applies to any platform. GoalHow to Replace a SPARC T3-2 DVD Drives SolutionDISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure Time Estimate: 40 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: DVD failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
The components that require the server to be power down. These components can be replaced by customers.
Prepare for servicing: a. Attach an antistatic wrist strap. b. Remove any media from the drive. c. Power off the server and unplug power cords from the power supplies. WHAT ACTIONS ARE REQUIRED: Remove and Install DVD Drivers For Removing 1. Push down on the latch on the top left corner of the DVD drive or filler panel. 2. Slide the DVD drive or filler panel out of the server. Caution: Whenever you remove the DVD drive or filler panel, you should replace it with another DVD drive or a filler panel; otherwise the server might overheat due to improper airflow. For Installing- 1. Unpack the DVD drive or filler panel. If it is a DVD drive, attach an antistatic wrist wrap and place the drive on an antistatic mat. 2. Slide the DVD drive or filler panel into the front of the chassis until it seats. 3. Return the server to operation: a. Return the server to the normal rack position. b. Reinstall the power cords to the power supplies and power on the server. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Verify functionality, no service LEDs or messages. PARTS NOTE: REFERENCE INFORMATION: SPARC T3-2 Server Documentation: http://docs.oracle.com/cd/E19166-01/index.html Attachments This solution has no attachment |
||||||||||||||
|