Asset ID: |
1-71-1334656.1 |
Update Date: | 2016-03-11 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1334656.1
:
How to Replace a Sun Netra T5440 Optical (DVD) Media Drive:ATR:1334656.1:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
Applies to:
Sun Netra T5440 Server - Version All Versions and later
Information in this document applies to any platform.
Goal
Replace a Sun Netra T5440 Optical Drive (DVD)
*****************************************************************************************
To report errors or request improvements on this procedure, please add a comment on Doc ID: 1334656.1
*****************************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure
Time Estimate: 30 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS:
PROBLEM OVERVIEW: Optical Drive failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Shut down system and Power down the server.
To prepare the server optical media drive removal. Proceed with the following steps:
Powering Off the Server
Performing Antistatic Measures
WHAT ACTIONS ARE REQUIRED?:
Removing optical media drive
1. Open the bezel.
2. Pull the release tab out and to the left, freeing the optical media drive and attached housing.
3. Pull the rear release lever out and to the right, freeing the optical media drive from the housing
4. Set the optical media drive aside on an antistatic mat.
Installing optical media drive
1. Remove the replacement optical media drive from its packaging and place it on an antistatic mat.
2. Seat the optical media drive into the housing and secure it by pressing the rear release lever to the right.
3. Hold the tab to the left and insert the optical media drive into the media bay assembly.
4. Press the optical media drive in until it seats and close the release the tab by pressing it to the right
5. Close the bezel.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Restart the system back on line.
PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#RemovableMedia
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19874-01/820-4445-13/z40004061006939.html#i1001328
Attachments
This solution has no attachment