Asset ID: |
1-71-1333857.1 |
Update Date: | 2017-03-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1333857.1
:
SunFire V480/V490 How to Update FlashPROM FW:ATR:997:3
Related Items |
- Sun Fire V490 Server
- Sun Fire V480 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Sun Fire V490 Server - Version Not Applicable and later
Sun Fire V480 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
******************************************************************************
To report errors or request improvements on this procedure,
please go to https://support.us.oracle.com and put a comment on Doc ID: 1333857.1
******************************************************************************
How to Update V480 - V490 FlashPROM FW
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire V480/V490 Server
- TIME ESTIMATE: 30 min
- TASK COMPLEXITY: 3
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
Down Rev FW
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
Customer should take normal precautions to backup data, notify users of maintenance and that system will be powered down. Customer should conduct an orderly software system shutdown.
Note:
Use max post only when searching for IO Controller issues, Fatal Resets, and Unrecoverable Errors(UEs) that Solaris is unable to properly diagnose. If diag-level is set to max at OBP, confirm with customer that if can be moved to the factory default of min.
See: Guidance for POST Diagnostic Level Setting on Sun Fire[TM] 280R, V480, V490, V880, V890 and V880z servers. (Doc ID
1582330.1) for details.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
To determine what version of firmware is current, and download current firmware See <Document 1342226.1>
1) Determine system's current Flash PROM firmware revision. To determine the current version from the Solaris prompt type:
/usr/sbin/prtconf -V
or
/usr/platform/sun4u/sbin/prtdiag -v | grep OBP
The firmware revisions may also be determined from the PROM monitor's
"ok" prompt with the following command;
.version
2) Compare current Flash PROM firmware revision with available Flash PROM firmware revision.
3) If current Flash PROM firmware revision is lower than provided firmware revision in patch, then proceed to next step. If NOT, STOP: DO NOT CONTINUE.
4) Prepare system for Flash PROM update
a) As root, copy "flash-update" file from directory containing patch to the root directory as follows:
# cp flash-update* /
# chmod 755 /flash-update*
In order to boot binary, it must be located within root partition.
b) As root, exit OS such that system returns to PROM's "ok" prompt
c) Jumper J1104 is factory-set so that flash PROM is write-enabled. There is no need to switch jumper before flash updating; however, you must ensure that keyswitch is in Power-on or Diagnostics position. When key switch is in locked position flash PROM is write protected.
5) Running Flash PROM Utility
a) Power on system, wait for PROM's banner to appear, then
b) Use Stop-A keys (or Break key, if running from a serial line) to abort auto-boot sequence.
c) System should now display PROM monitor's "ok" prompt.
d) Boot Flash update utility with: ok boot disk /flash-update-SunFire480
6) Verify successful Flash PROM Update
7) Restore system & resume operations
a) Allow system to auto-boot, or issue boot command for environment as necessary.
b) Once system has rebooted you may wish to remove Flash Update binaries & documents since they will no longer be needed. # rm /flash-update*
c) Remember to remove files from their original location if not extracted directly into root directory. ok setenv diag-script normal ok reset-all
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Start software applications per applicable administration guides to resume system operation.
PARTS NOTE:
None
REFERENCE INFORMATION:
Refer to install.info document available w/ patch, before starting FW upgrade
http://download.oracle.com/docs/cd/E19095-01/sfv480.srvr/index.html
http://download.oracle.com/docs/cd/E19095-01/sfv490.srvr/index.html
Attachments