How to Replace a Sun Fire/Enterprise T1000 Server Fan Tray:ATR:1333621.1:0
Related Items |
- Sun SPARC Enterprise T1000 Server
- Sun Fire T1000 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire T1000 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun SPARC Enterprise T1000 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire T1000 Server Fan Tray
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
The customer should conduct an orderly software and system shutdown.
System power off is required.
WHAT ACTIONS ARE REQUIRED:
1. Ensure system is shut down
2. Follow instructions in chapter 4 (Sun Fire T1000 Server Service Manual) to prepare the system for service.
The chassis cover might be very difficult to remove. If you press too hard on the cover lock button, the front edge of the cover might warp and bind. Also, elastic gasket material on the sides of the chassis might prevent the cover from sliding freely.
To work around this, lightly hold down the cover lock button and push the cover slightly toward the front of the chassis (this assists the unlocking action), then slide the cover approximately one half inch (12 mm) toward the rear of the chassis. You can now lift the cover off the chassis.
3. Disconnect the fan power cable from the motherboard.
4. Push in on the clasps on both sides of the fan assembly
5. Remove the fan assembly from the sheet metal mounting brackets.
6. Unpack the replacement fan tray assembly and place it on an antistatic mat.
7. Align the fan tray assembly with the sheet metal mounting brackets and slide it into place until the clasps on each side lock it into place.
8. Reconnect the fan power cable to the motherboard.
9. Follow instructions in Chapter 6 (Sun Fire T1000 Server Service Manual) to finish up hardware servicing.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Power on the server.
PARTS NOTE:
541-0582
https://support.oracle.com/handbook_private/Systems/SunFireT1000/components.html#Fan
https://support.oracle.com/handbook_private/Systems/SE_T1000/components.html#Fan
REFERENCE INFORMATION:
Sun Fire T1000 Server Service Manual