Asset ID: |
1-71-1332318.1 |
Update Date: | 2018-05-21 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1332318.1
:
How to Replace a Sun Fire X4275 PCIe Card
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4275 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4275 PCIe Card.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 45 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4275 PCIe Card needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Customer should perform an orderly and graceful shutdown of applications and OS
A data backup is not a pre-requisite but is a wise precaution
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD procedures
1. Power off the server and unplug (REMOVE) the power cords from power supplies
2. Remove the top cover
3. Locate the PCIe card to be removed and it's corresponding rise
4. Label and make note of the of where PCIe cards and cabling is installed
5. Unplug data cables from the PCIe card to be removed
6. Remove the screw that secures the PCIe riser to the motherboard. Remove the riser
7. Remove the PCIe card from the PCIe riser connector
8. Install the replacement PCIe card into the PCIe riser connector
9. Re-install the PCIe riser and tighten the screw to secure to the motherboard
10.Re-connect the cables
15. Replace the main cover
16. Re-connect the power cords
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19871-01/820-5830-13/index.html
Attachments
This solution has no attachment