Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1332213.1
Update Date:2018-05-22
Keywords:

Solution Type  Technical Instruction Sure

Solution  1332213.1 :   How to Replace a Sun Fire X4275 HDD  


Related Items
  • Sun Fire X4275 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Applies to:

Sun Fire X4275 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4275 HDD.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4275 HDD needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The BIOS RAID utility or Operating System should be configured by the customer such that the disk drive is free for replacement.
E.g. The disk may be part of BIOS RAID configuration, Volume Management software, mounted file-system, raw partitions, etc.
A data backup is recommended as a precaution and may be required to restore data onto a replaced disk.
Orderly shutdown of applications and OS may be required if the disk being replaced is the boot device and no mirroring is in place. Customer will need to restore/recover from backup

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Locate the hard disk drive to be replaced by viewing the LED on the front of the drives. If middle LED is amber, this indicates the drive is faulty
2. Ensure the correct hard disk drive is being replaced and label if necessary. Press the button on the front to release the spring loaded lever.
3. Grasp the handle and remove the drive from the bay
4. Open the latch of the replacement hard disk drive and insert into the bay
5. Push the drive into the bay until it stops. Close the spring loaded lever handle to engage the hard disk drive to the hard disk backplane

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Customer to verify drive availability
Customer to use appropriate software commands to re-activate/re-sync mirror if manual intervention is required

PARTS NOTE:
None

REFERENCE INFORMATION:

Sun Fire X4170, X4270, and X4275 Servers Service Manual 820-5830-11
Sun Disk Management Overview 820-6350-15
Sun LSI 106x RAID User's Guide 820-4933-15
Sun StorageTek RAID Manager Software User's Guide 820-1177-13

All located here:
http://download.oracle.com/docs/cd/E19871-01/

Detailed SVM instructions can be found at
http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html

See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions

References

<NOTE:1002753.1> - How to Replace a Drive in Solaris[TM] ZFS
<NOTE:1010946.1> - General Guidance for Diagnosis (Disk Failures/Errors) and Replacing Internal Server Disks and JBOD Disks within Solaris

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback