Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1329203.1
Update Date:2017-02-27
Keywords:

Solution Type  Technical Instruction Sure

Solution  1329203.1 :   VSM/SVA - Power FSC79F0 or FSC79F1, then FSC7A00 or FSC7A01  


Related Items
  • Sun StorageTek VSM System
  •  
  • Sun StorageTek VSM4 System
  •  
  • Sun StorageTek V2X SVA Disk System
  •  
  • Sun StorageTek VSM5 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Datacenter Disk - Other
  •  
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Goal
Solution


Created from <SR 3-3782400277>

Applies to:

Sun StorageTek V2X SVA Disk System - Version Not Applicable and later
Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
Sun StorageTek VSM4 System - Version All Versions to All Versions [Release All Releases]
Sun StorageTek VSM5 System
Information in this document applies to any platform.

Goal

Troubleshooting Power FSC79F0 or FSC79F1 followed later by FSC7A00 or FSC7A01

Solution

FSC79F0 and FSC79F1 indicate a loss of AC power to region 0 and region 1 respectively
FSC7A00 and FSC7A01 indicate a return of AC power to region 0 and region 1 respectively

This combination of FSC codes often occurs when the customer has had a site power outage and recovered, or is working on their site power/UPS.

1. Connect to the box and verify there are no fenced power supplies

2. If there is one or more fenced power supplies, send an FSE on site to either GFR/no replace the power supply, or GFR/replace the power supply.