Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1325039.1
Update Date:2017-10-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  1325039.1 :   DIMM Size Reference Sheet for Sun Fire Midrange and Highend Servers  


Related Items
  • Sun Enterprise 5500 Server
  •  
  • Sun Fire E25K Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Enterprise 5000 Server
  •  
  • Sun Enterprise 4000 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Enterprise 3500 Server
  •  
  • Sun Enterprise 3000 Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire V490 Server
  •  
  • Sun Enterprise 6000 Server
  •  
  • Sun Enterprise 10000 Server
  •  
  • Sun Fire 15K Server
  •  
  • Sun Fire V480 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Enterprise 6500 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Enterprise 4500 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire V890 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  




In this Document
Goal
Solution
 
 Sun Enterprise Classic Servers (3x00, 4x00, 6x00)
 
 Sun Enterprise 10000 Server (E10K)
 
 Workgroup Servers (v480/v490/v880/v890)
 
 Lightweight 8 Servers (n1280/n1290/v1280/v1290/E2900)
 
 Sun Fire Serengeti Servers (3800/48x0/E4900/6800/E6900)
 
 Sun Fire Starcat Servers (E12K/E15K/E20K/E25K)
References


Applies to:

Sun Fire V490 Server - Version Not Applicable and later
Sun Enterprise 6000 Server - Version Not Applicable and later
Sun Enterprise 5500 Server - Version Not Applicable and later
Sun Enterprise 10000 Server - Version Not Applicable and later
Sun Enterprise 6500 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

This is a DIMM Size Reference.  It's purpose is to help a user quickly identify the size of a DIMM installed in their particular system utilizing the prtdiag command output.  This is not the only mechanism that can be used to identify DIMM size on these platforms - It is simply a quick method that can be used if other data is not readily available.

The systems included in this reference are:

  • Sun Enterprise 10000 (E10K)
  • Sun Fire 12K, 15K, E20K, E25K
  • Enterprise 3000, 3500, 4000, 4500, 5000, 5500, 6000, 6500 (exx00)
  • Sun Fire v1280, E2900, 3800, 4800, 4810, 6800, E4900, E6900, and Netra 1280, 1290

For VSP SPARC systems, please utilize <Document:1006832.1>.
 

Solution

ATR Tools - DIMM Reference Table
NOTE:  This document was created when the Systems TSC organization identified that too many action plans included incorrect part numbers for DIMM replacements. Before creating an action plan, please be certain the proper DIMM size for the appropriate platform type has been selected. Use the following information to determine the correct DIMM part size or consider using showfru to provide the part number automatically.
 

Sun Enterprise Classic Servers (3x00, 4x00, 6x00)

    Rule:  Physical DIMM Size = "MB" entry in prtdiag divided by 8.

"MB" entry in prtdiag shows:

64MB

256MB

1024MB

2048MB

Physical DIMM size is:

8MB

32MB

128MB

256MB



Sun Enterprise 10000 Server (E10K)

    Rule:  Physical DIMM Size = "Memory Unit Size" entry in prtdiag divided by 8.

"Memory Unit Size" entry in prtdiag shows:

256MB

1024MB

Physical DIMM size is:

32MB

128MB



Workgroup Servers (v480/v490/v880/v890)

    Rule:  Physical DIMM Size = "DIMM Size" entry in prtdiag.

"DIMM Size" in prtdiag    IS   the Physical DIMM size.



Lightweight 8 Servers (n1280/n1290/v1280/v1290/E2900)

    Rule:  Physical DIMM Size = "Size" entry in prtdiag divided by 2.

"Size" entry in prtdiag shows:

512MB

1024MB

2048MB

Physical DIMM size is:

256MB

512MB

1024MB (1GB)




Sun Fire Serengeti Servers (3800/48x0/E4900/6800/E6900)

    Rule:  Physical DIMM Size = "DIMM Size" entry in prtdiag.

"DIMM Size" in prtdiag    IS   the Physical DIMM size.



Sun Fire Starcat Servers (E12K/E15K/E20K/E25K)

    Rule:  Physical DIMM Size = "DIMM Size" entry in prtdiag.

"DIMM Size" in prtdiag   IS   the Physical DIMM size.