Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1319385.1
Update Date:2017-09-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  1319385.1 :   SL500 - How to Change CAP From I/O to Storage Cell Function  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only

Applies to:

Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

SL500 - How to Change CAP From I/O to Storage Cell Function

Solution

To change the function of the CAP (Cartridge Access Port) from I/O (Input/Output) operation to Storage cells, the following must be done:

Log in to CLI port with the "service or remote" user:

To print the current CAP configuration Enter the command: capconfig print

Example:   SERVICE>> capconfig print
               Module 1: io


Enter the command: cap x io or storage  (x = module number)

     Example: cap 1 storage 
                      cap 1 io

A reboot of the SL500 is needed to enable the change.  The default of the CAP is I/O.
A Field Service Representative is required to enable this function.  It is not available via SL Console.

Refer to the SL500 Installation Manual, Chapter 4, Configuring the Library, for command information.

 

A Webex Session could be created with the CU to do all these steps in order to configure the CAP.

 