Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1318118.1
Update Date:2018-05-17
Keywords:

Solution Type  Technical Instruction Sure

Solution  1318118.1 :   How to Replace a Sun Fire X4540 SSD  


Related Items
  • Sun Fire X4540 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire X4540 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4540 SSD.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4540 SSD needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

* This component is a hot-pluggable customer-replaceable unit (CRU) and can be replaced by anyone. Hot-pluggable means that the drive must be first brought offline by using a management software or operating system command; however, the server does not need to be powered off.
* Removing a hard disk or solid state disk (SSD) before it has been prepared for removal by the software can cause data loss.
* Before removing a drive, have the replacement drive ready to be installed.
* To avoid overheating the server, if the server is powered on, do not leave a drive out for longer than 60 seconds at a time. Remove and replace only one drive at a time. Replace the drives access cover as soon as the service tasks are completed.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
* Remove the drives access cover.
* Identify the drive to be removed by checking its LEDs.
* Use the operating system or management software to take the disk drive offline before you replace it. If the middle LED is on (amber), the drive is faulty and should be replaced. Once the drive has been taken off line, the left (blue) LED should turn on. This means the drive is ready to be removed and service action is allowed.

Note - If you are using the operating system command line, note that disks in the enclosure are typically identified in sequential order. Although the enclosure contains only 48 disks, your operating system may see a list of 51 devices; if this is the case, the first 4 addresses (0-3) represent the enclosure's four SAS expanders, the other 48 addresses (4-51) represent the 48 drives.
* Remove the drive. Lift the metal latch and remove the drive from the drive bay, or on the service label.
* Install the replacement SSD (in drive bracket) into the drive bay of the system. Push the drive into the bay until it stops and is fully engaged with the connector on the drive backplane. Push down the metal handle so it properly locks into place.
* Replace the disk drives access cover.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
* Configure the new disk drive.
- Refer to your operating system documentation for information on adding a new disk drive.
Note - If the drives were previously configured as a RAID 1 (or higher) array, an automatic resynchronization is invoked and the contents are automatically rebuilt from the rest of the array with no need to reconfigure the RAID parameters. If the bad drive was configured as a spare, the new drive is automatically configured as a new spare.
PARTS NOTE:

REFERENCE:

Sun Fire X4500/X4540 Server Service Manual

http://download.oracle.com/docs/cd/E19469-01/819-4359-19/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback