How to Replace a Sun Fire X4540 Power Supply
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4540 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4540 Power Supply.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4540 Power Supply needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Remove a Power Supply
If present, remove cable management arm, or swivel open cable management arm to view power supplies.
Disconnect the AC power cord that is connected to power supply you want to replace.
Remove installed power supply unit by pulling its handle downward until it disengages unit from connector on PDB. Pull out power supply.
Install a Power Supply
Align power supply with empty bay in chassis.
With power supply handle in down position, push power supply into power supply bay.
Connect AC power cord to new power supply. Use the power cord retaining clips
If present, swivel cable management arm back into closed position.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE:
Sun Fire X4500/X4540 Server Service Manual
http://download.oracle.com/docs/cd/E19469-01/819-4359-19/index.html
Attachments
This solution has no attachment