Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1317999.1
Update Date:2018-05-17
Keywords:

Solution Type  Technical Instruction Sure

Solution  1317999.1 :   How to Replace a Sun Fire X4500 Power Distribution Board  


Related Items
  • Sun Fire X4500 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: CAP

Applies to:

Sun Fire X4500 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4500 Power Distribution Board.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4500 Training

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4500 Power Distribution Board needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.

System needs to be shutdown

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Power off the server.

2. Remove the system controller.

3. Remove all power supplies.

4. From the back of the enclosure, remove the power supply cover.

5. Remove the cable management arm (CMA) mounting plate (power supply filler panel).

6. Remove the PDB:

7.Install the new PDB:

8.Reinstall the CMA mounting plate.

9. Reinstall the power supply cover.

10.Install or reinstall the power supplies:

11. Reinstall the system controller.

12. Reinstall the disk drive access cover.

13. Reconnect AC power cords to the power supplies.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Boot system and test functionality. Monitor boot sequence and check prtdiag, fmdump, and dmesg.

PARTS NOTE: N/A

REFERENCE INFORMATION:

See the section "To replace the power distribution board (FRU)" in the

Sun Fire X4500/X4540 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x4500/819-4359-19/index.html