1317596.1
:
How to Replace a Sun Fire X4440 Air Duct
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4440 Air Duct.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4440 Air Duct needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
1. Power off server
2. Disconnect power cords from power supply
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Slide server out of rack
2. Attach antistatic wrist strap
3. Remove top cover
Removing the Air Duct
1. Remove mezzanine tray, to access air duct
2. Lift air baffle out of mezzanine tray
3. Slide motherboard air duct to right to disengage pin on left side
4. Slide air duct to left to disengage pin on right side
5. Move air duct towards back to clear lip on midwall
6. Lift air duct out of server
7. Set air duct aside
Installing the Air Duct
1. Reverse the Removing process
Return Server to Operation
1. Reinstall mezzanine tray
2. Install top cover
3. Install server into rack
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Bring system back online
PARTS NOTE:
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19121-01/sf.x4440/820-3836-14/820-3836-14.pdf
Attachments