Asset ID: |
1-71-1317584.1 |
Update Date: | 2018-05-21 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1317584.1
:
How to Replace a Sun Fire X4440 Paddle Card
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire X4440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4440 Paddle Card.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4440 Training
TIME ESTIMATE: 90 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4440 Paddle Card needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
* Power Off the Server
* Extend the Server to the Maintenance Position
* Remove Server From the Rack
* Perform Electrostatic Discharge and Antistatic Prevention Steps
* Remove the Top Cover
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removing the Paddle Card
* Remove the motherboard assembly.
* Remove the power distribution board.
* Remove the fan power boards.
* Remove the two No. 2 Phillips screws securing the Paddle card to the chassis.
* Slide the Paddle card back, away from its connector on the drives backplane.
* Lift the Paddle card up and out of the chassis.
* Place the Paddle card on an antistatic mat.
Installing the Paddle Card
* Lower the Paddle card into the chassis.
The Paddle card card fits over a series of mushroom standoffs in the chassis side wall.
* Slide the Paddle card forward to plug it into the drives backplane.
* Secure the Paddle card with two No. 2 Phillips screws.
* Install the fan power boards.
* Install the power distribution board.
* Install the motherboard assembly.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4440 Server Service Manual - Servicing the Front Control Panel Light Pipe Assembly, Chapter 5.4
http://download.oracle.com/docs/cd/E19121-01/sf.x4440/820-3836-14/index.html
Attachments
This solution has no attachment