Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1317584.1
Update Date:2018-05-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  1317584.1 :   How to Replace a Sun Fire X4440 Paddle Card  


Related Items
  • Sun Fire X4440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire X4440 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4440 Paddle Card.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4440 Training

TIME ESTIMATE: 90 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4440 Paddle Card needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

* Power Off the Server
* Extend the Server to the Maintenance Position
* Remove Server From the Rack
* Perform Electrostatic Discharge and Antistatic Prevention Steps
* Remove the Top Cover


WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Removing the Paddle Card

* Remove the motherboard assembly.
* Remove the power distribution board.
* Remove the fan power boards.
* Remove the two No. 2 Phillips screws securing the Paddle card to the chassis.
* Slide the Paddle card back, away from its connector on the drives backplane.
* Lift the Paddle card up and out of the chassis.
* Place the Paddle card on an antistatic mat.

Installing the Paddle Card

* Lower the Paddle card into the chassis.
The Paddle card card fits over a series of mushroom standoffs in the chassis side wall.
* Slide the Paddle card forward to plug it into the drives backplane.
* Secure the Paddle card with two No. 2 Phillips screws.
* Install the fan power boards.
* Install the power distribution board.
* Install the motherboard assembly.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:

Sun Fire X4440 Server Service Manual - Servicing the Front Control Panel Light Pipe Assembly, Chapter 5.4

http://download.oracle.com/docs/cd/E19121-01/sf.x4440/820-3836-14/index.html