Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1317348.1
Update Date:2016-01-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1317348.1 :   How to Remove and Replace an X6440 REM (RAID Expansion Module):ATR:2296:2  


Related Items
  • Sun Blade 6000 System
  •  
  • Sun Blade X6440 Server Module
  •  
  • Sun Blade 6048 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Oracle Confidential (INTERNAL). Do not distribute to customers.
Reason: FRU CAP

Applies to:

Sun Blade X6440 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

X6440 REM (RAID expansion module) Replacement

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
X6440 trained

TASK COMPLEXITY: 2

TIME ESTIMATE: 60 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

* The server must be fully shut down and the power cords disconnected.
* Do not operate the system with empty slots. Always insert a filler panel into an empty slot to reduce the possibility of system shut down.
* Take ESD Precautions.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Power off the server and remove the server module from the chassis

2. Remove the main cover

3. If the REM board uses a backup battery, disconnect the jumper cable between the REM board and chassis motherboard.

4. Remove the existing REM board or the cap(s) from the REM connector(s) if either is present.

5. Slide the REM board at an angle into the support bracket, then press it carefully into the connector.

6. If the REM board uses a backup battery, connect the jumper cable between the REM board and chassis motherboard.

7. Installation is the reverse of this procedure.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Verify functionality, no service LEDs or messages

PARTS NOTE:

REFERENCE INFORMATION:

Sun Blade X6440 Server Module Service Manual

http://download.oracle.com/docs/cd/E19045-01/blade.x6440/820-3964-10/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback