Goal
X6440 REM (RAID expansion module) Replacement
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
X6440 trained
TASK COMPLEXITY: 2
TIME ESTIMATE: 60 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
* The server must be fully shut down and the power cords disconnected.
* Do not operate the system with empty slots. Always insert a filler panel into an empty slot to reduce the possibility of system shut down.
* Take ESD Precautions.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server and remove the server module from the chassis
2. Remove the main cover
3. If the REM board uses a backup battery, disconnect the jumper cable between the REM board and chassis motherboard.
4. Remove the existing REM board or the cap(s) from the REM connector(s) if either is present.
5. Slide the REM board at an angle into the support bracket, then press it carefully into the connector.
6. If the REM board uses a backup battery, connect the jumper cable between the REM board and chassis motherboard.
7. Installation is the reverse of this procedure.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify functionality, no service LEDs or messages