Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1316516.1
Update Date:2016-01-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1316516.1 :   How to Replace a Sun ZFS Unified Storage Appliance 7120 Fan Board Assembly:ATR:1316516.1:2  


Related Items
  • Sun ZFS Storage 7120
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
  •  




In this Document
Goal
Solution
 
 To report errors or request improvements on this procedure, please add a comment
References


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Sun ZFS Storage 7120 - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

How to Replace a 7120 Fan Board Assembly ( Doc 1316516.1 )

 

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE CUSTOMER/ENGINEER NEED:
Training and experience with 7120 NAS hardware and administration.

DELIVERY REQUIREMENT: As required

TIME ESTIMATE: 60 minutes

FIELD INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

1. Refer to the BUI for exact slot locations for Fan Board "Maintenance -> Hardware -> show details -> Fan".

2. Shut down the appliance before beginning this task and disconnect the AC power chords.


WHAT ACTION DOES THE CUSTOMER/ENGINEER NEED TO TAKE:

1. Remove server from rack and attach antistatic wrist strap

2. Remove top cover(s)

3. Remove Fan Board Assembly

3.1 Remove the fan modules. See the fan module replacement procedure. (Doc ID 1316498.1)
3.2 Open the middle section to expose the SAS expander module and remove the module.
3.3 Slide the fan power board to the right to disengage it from the standoffs.
3.4 Disconnect the two cables attached to its underside.

4. Install Fan Board Assembly
4.1 Connect the two cables to the replacement fan power board's underside.
4.2 Slide the fan power board to the left to engage the standoffs.
4.3 Secure it to the chassis.
4.4 Reinstall the SAS expander module, then close the middle section of the fan standoffs.
4.5 Reinstall the fan modules.

5. Return system to operational state
5.1 Reseat the top cover on the chassis.
5.2 Close the fan cover and engage the fan cover latches.
5.3 Reinstall the appliance back in its original rack location.
5.4 Reconnect the cables to the back of the storage controller.
5.5 Connect the power cords.
5.6. Verify that standby power is on, indicated by the Power/OK LED flashing on the front panel about two minutes after the power cords are plugged in.
5.7 Use a pen, or other pointed object, to press and release the recessed Power button on the storage controller front panel. The Power/OK LED next to the Power button lights and remains lit. SSH to the service processor (SP) and check appliance power state, show /SYS power_state. If status is off issue the "start SYS" command to power up the appliance.
5.8 You must follow the procedure for creating a service account on the SP and copying the Product Serial Number to the Fan Board found in Sun ZFS Storage 7X20 Appliance Field Service Guide.

OBTAIN CUSTOMER ACCEPTANCE

Confirm the appliance is in a normal state. Check both BUI access and client data access.

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Confirm there are no faults reported in the appliance BUI. Maintenance -> Problems or Maintenance -> Hardware -> show details -> Fan

PARTS: 541-4124 - Fan Board Assembly

REFERENCES:

 For beside issues please have a look into Document:1324444.1 - Sun Storage 7000 Unified Storage System: Fan Troubleshooting

NOTE:

Incorrect handling when removing a fan module might damage to the fan board connectors. Please check KM Doc How to Replace a 7120 Fan Module:ATR:1316498.1:1

 

To report errors or request improvements on this procedure, please add a comment

References

https://support.us.oracle.com/handbook_internal/data/821/821-0488/pdf/821-0488-11.pdf
http://dogoro.us.oracle.com/wiki/index.php/Main_Page
Oracle Unified Storage Systems Documentation : http://www.oracle.com/technetwork/documentation/oracle-unified-ss-193371.html
<NOTE:1432269.2> - Information Center: Sun ZFS Storage Appliances
https://stbeehive.oracle.com/teamcollab/wiki/ZFSSAFieldSupport
http://fgw.sfbay.sun.com/twiki-bin/viewfile/FishPublic/WebHome?filename=FRU2011.pdf
<NOTE:1416406.1> - Sun ZFS Storage Appliances Troubleshooting Resource Center

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback