How to Replace a Sun Fire X4470 DVD Drive
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4470 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4470 DVD Drive.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4470 DVD Drive needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
1. Attach an antistatic wrist strap.
When servicing or removing server components, attach an antistatic strap to your wrist and then to a metal area on the chassis.
2. Remove any media from the drive.
3. Power off the server.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Removing DVD Drive
1.1 Push down on the latch on the top left corner of the DVD drive or filler panel.
1.2 Slide the DVD drive or filler panel out of the server.(you should replace with another DVD drive or filler panel; otherwise server might overheat due to improper airflow)
2. Installing DVD Drive
2.1 Unpack the DVD drive or filler panel (If it is a DVD drive, place it on an antistatic mat)
2.2 Slide the DVD drive or filler panel into the front of the chassis until it seats.
3. Return the server to operation
3.1 Power on the server.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.
PARTS NOTE:
REFERENCE INFORMATION:
X4470 Service Manual:
http://download.oracle.com/docs/cd/E19694-01/E21739-01/z400085b1296702.html