Asset ID: |
1-71-1316404.1 |
Update Date: | 2018-05-18 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1316404.1
:
How to Replace a Sun Fire X4470 HDD
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4470 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4470 HDD.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4470 HDD needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
1. Determine whether you can replace the disk drive using the hot-plug procedure or whether you need to power off the server and use the cold-swap procedure.
* A cold-swap is required if the disk drive:
o Contains the operating system, and the operating system is not mirrored on
another drive.
o Cannot be logically isolated from the online operations of the server.
2. Do one of the following:
1. To cold-swap the drive, power off the server.
2. To hot-plug the drive, take the drive offline. This removes the logical software links to the drive and prevents any applications from accessing it.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removing and Installing Disk Drives and Disk Drive Filler Panels
1. Attach an antistatic wrist strap.
2. Identify the disk drive filler panel you want to remove. The amber Service Action Required LED on the drive might be lit.
3. On the disk drive filler panel you want to remove, push the release button to open the latch.
4. Grasp the latch and pull the filler panel out of the drive slot.
Caution â The latch is not an ejector. Do not bend it too far to the right. Doing so can damage the latch.
Remove a Disk Drive
1. On the drive you plan to remove, push the disk drive release button to open the latch.
2. Grasp the latch and pull the drive out of the drive slot.
Install a Disk Drive
1. Unpack the disk drive and place it on an antistatic mat.
2. Verify that the release lever on the disk drive is fully opened.
3. Slide the drive into the drive slot until it is fully seated.
4. Close the latch to lock the drive in place.
5. Do one of the following:
1. If you have cold-swapped the drive, restore power to the server.
2. If you have hot-plugged the drive, configure the disk drive.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
For hot plug, configure the drive and verify drive availability.
Use appropriate software commands to re-activate/re-sync mirror if manual intervention is required
PARTS NOTE:
REFERENCE INFORMATION:
X4470 Service Manual:
http://download.oracle.com/docs/cd/E19694-01/E21739-01/z40008571293590.html
Detailed SVM instructions can be found at
http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html
See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions
References
<NOTE:1002753.1> - How to Replace a Drive in Solaris[TM] ZFS
<NOTE:1010946.1> - General Guidance for Diagnosis (Disk Failures/Errors) and Replacing Internal Server Disks and JBOD Disks within Solaris
Attachments
This solution has no attachment