Asset ID: |
1-71-1316267.1 |
Update Date: | 2018-05-23 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1316267.1
:
How to Replace a Sun Fire X4270 M2 Rear Disk Drive Cage
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire X4270 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4270 M2 Rear Disk Drive Cage.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4270 M2 Training
TIME ESTIMATE: 90 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4270 M2 Rear Disk Drive Cage needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
1. Prepare the server for service.
a. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
b. Remove the server from the rack.
c. Attach an antistatic wrist strap.
d. Remove the top cover.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
2. Remove the rear-mounted boot disk drive cage
a. Loosen the two captive Phillips screws on the ends of the PCI crossbar.
b. Grasp both ends of the PCI crossbar and pull it to the rear to disengage it from the chassis and then lift it up and out of the chassis.
c. Disconnect the two SATA cables connectors from the rear of the boot disk drive cage.
d. Disconnect the power cable from the rear of the boot disk drive cage.
e. Remove the two green captive screws that secure the boot disk drive cage to the server chassis.
f. Lift the cage up and out of the chassis.
3. Place the cage on an antistatic mat.
4. Install the rear-mounted boot disk drive cage
a. Lower the boot disk drive cage into the server chassis
b. Tighten the two green captive that secure the cage to the chassis
c. Reconnect the boot disk drive cage power cable connector
d. Reconnect the two SATA cable connectors to the disk drive cage
e. Lower the PCI crossbar down into the chassis and then move it forward to engage the chassis and the rear-mounted components
f. Tighten the two captive Phillips screws that secure the PCI crossbar to the chassis
5. Return the server to operation.
a. Install the top cover.
b. Return the server to the normal rack position.
c. Reconnect the power cord(s) to the power supply (or supplies) and power on the server. Verify that the AC Present LED is lit.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE INFORMATION
Attachments
This solution has no attachment