Solution Type
Technical Instruction Sure
Solution
1316262.1
:
How to Replace a Sun Fire X4270 M2 SAS Expander Card
Related Items |
- SPARC SuperCluster T4-4 Full Rack
- Exadata Database Machine X2-2 Qtr Rack
- Sun Fire X4270 M2 Server
- Exadata Database Machine X2-2 Full Rack
- Exadata Database Machine X2-8
- Big Data Appliance Hardware
- Exadata Database Machine X2-2 Half Rack
- SPARC SuperCluster T4-4 Half Rack
- Exadata Database Machine X2-2 Hardware
- SPARC SuperCluster T4-4
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
SPARC SuperCluster T4-4 - Version All Versions and later
Sun Fire X4270 M2 Server - Version All Versions and later
Big Data Appliance Hardware - Version All Versions and later
Exadata Database Machine X2-2 Qtr Rack - Version All Versions and later
Exadata Database Machine X2-2 Half Rack - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4270 M2 SAS Expander Card.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4270 M2 Training
TIME ESTIMATE: 75 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4270 M2 SAS Expander Card needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Customer should perform an orderly and graceful shutdown of applications and OS
A data backup is not a pre-requisite but is a wise precaution
Note:
If this server is part of an Exadata, please follow shutdown instructions in DOC ID: 1188080.1
If this server is part of a Big Data Appliance, please follow shutdown instruction in DOC ID: 2099858.1
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Caution - Ensure that all power is removed from the server before removing or installing the SAS expander board. You must disconnect the power cables before performing these procedures.
1. Prepare the server for service.
a. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
b. Remove the server from the rack.
c. Attach an antistatic wrist strap.
d. Remove the top cover.
e. If you are removing the SAS expander board from a server with 2.5-inch storage drives, remove the server’s front cover.
2. Remove fan modules 1 through 4, leaving fan modules 0 and 5 in place.
3. Removing the SAS expander board.
a. Locate the SAS expander board.
b. To gain access the SAS expander board, press the latch release on the disk expander access door on the fan board and open the door.
c. Loosen the two green Phillips screws that secure the SAS expander board bracket to the server’s chassis.
d. Grasp the sides of the bracket and slide it toward the rear of the server chassis to disengage the SAS expander board from the disk backplane.
e. Turn the bracket over and disconnect the SAS cables connected to the underside of the SAS expander card.
Note - The SAS expander card and its holding bracket are replaced as a unit.
f. Place the SAS expander board with its bracket on an antistatic mat.
4. Installing the SAS expander board.
a. Connect the SAS cables to the underside of the SAS expander board. If there is only one SAS cable, always connect it to the right port.
b. Lower the SAS expander board into the server chassis and slide it forward into the connectors on the disk backplane.
c. Install the two green Phillips screw to secure the SAS expander board to the chassis.
d. Close SAS expander board access door on the fan board.
5. Reinstall the fan modules.
6. Return the server to operation.
a. Install the top cover.
b. Return the server to the normal rack position.
c. Reconnect the power cord(s) to the power supply (or supplies) and power on the server. Verify that the AC Present LED is lit.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
Note:
If this server is part of an Exadata, please follow restart instructions in step 7 of DOC ID: 1188080.1
If this server is part of a Big Data Appliance, please follow restart instructions in DOC ID: 2099858.1
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4270 M2 Server Service Manual
http://docs.oracle.com/cd/E19245-01/E21671/index.html
Steps to shut down or reboot an Exadata storage cell without affecting ASM (Doc ID 1188080.1)
Steps to Gracefully Shutdown and Power on a Single Node on Oracle Big Data Appliance Prior to Maintenance (Doc ID 2099858.1)
Attachments