Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1316255.1
Update Date:2018-05-23
Keywords:

Solution Type  Technical Instruction Sure

Solution  1316255.1 :   How to Replace a Sun Fire X4270 M2 Power Supply Backplane  


Related Items
  • Sun Fire X4270 M2 Server
  •  
  • SPARC SuperCluster T4-4
  •  
  • SPARC SuperCluster T4-4 Full Rack
  •  
  • Big Data Appliance Hardware
  •  
  • Exadata Database Machine X2-2 Half Rack
  •  
  • SPARC SuperCluster T4-4 Half Rack
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Exadata Database Machine X2-8
  •  
  • Exadata Database Machine X2-2 Qtr Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

SPARC SuperCluster T4-4 - Version -Not Applicable- to -Not Applicable- [Release NA]
SPARC SuperCluster T4-4 Half Rack - Version -Not Applicable- to -Not Applicable- [Release NA]
Exadata Database Machine X2-2 Qtr Rack - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-2 Half Rack - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-2 Full Rack - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4270 M2 Power Supply Backplane.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4270 M2 Training

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4270 M2 Power Supply Backplane needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Customer should perform an orderly and graceful shutdown of applications and OS
A data backup is not a pre-requisite but is a wise precaution

Note:

If this server is part of an Exadata, please follow shutdown instructions in DOC ID: 1188080.1

If this server is part of a Big Data Appliance, please follow shutdown instruction in DOC ID: 2099858.1

 

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Prepare the server for service.
   a. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
   b. Remove the server from the rack.
   c. Attach an antistatic wrist strap.
   d. Remove the top cover.

Removing the power supply backplane
1. Remove the power supplies.
2. Remove the power distribution board.
3. Remove the power supply backplane.
   a. Disconnect the power supply ribbon cable from the power supply backplane.
   b. Remove the Phillips screw that secures the power supply backplane to the server’s chassis.
   c. Lift the power supply backplane up and forward to clear the mushroom standoffs and lift it out of the chassis.
4. Place the power supply backplane on an antistatic mat.

Installing the power supply backplane
1. Install the power supply backplane.
   a. Position the power supply backplane over the mushroom standoffs on the bracket and slide it down to engage the mushroom standoffs.
   b. To secure the power supply backplane to the server chassis, install the Phillips screw.
   c. Reconnect the power supply ribbon cable to the power supply backplane.
2. Install the power distribution board.
3. Install the power supplies.
4. Return the server to operation.
   a. Install the top cover.
   b. Return the server to the normal rack position.
   c. Reconnect the power cord(s) to the power supply (or supplies) and power on the server. Verify that the AC Present LED is lit.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot up system and verify full functionality

Note:

If this server is part of an Exadata, please follow restart instructions in step 7 of DOC ID: 1188080.1

If this server is part of a Big Data Appliance, please follow restart instructions in DOC ID: 2099858.1


PARTS NOTE:

REFERENCE INFORMATION:

Sun Fire X4270 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19245-01/E21671-02/index.html

Steps to shut down or reboot an Exadata storage cell without affecting ASM (Doc ID 1188080.1)
Steps to Gracefully Shutdown and Power on a Single Node on Oracle Big Data Appliance Prior to Maintenance (Doc ID 2099858.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.