Applies to:Sun Storage 6320 System - Version: Not Applicable and later [Release: N/A and later ]Information in this document applies to any platform. Goal6320 MIRE UpgradeSolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) 6320 product training TIME ESTIMATE: 60 minutes FIELD ENGINEER INSTRUCTIONS PROBLEM OVERVIEW: Array firmware upgrade required WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : Collect explorer/extractor Customer to perform backups as a precaution WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Require StorADE on laptop or access to StorADE on customer host Download latest upgrade ISO image from reference site below. Review matrix. Use Storage GUI Manager -> Service -> Revision Maintenance -> Create Patch Report -> Select Patches and select individual components to apply the patches in the below order. 1. Apply Service Processor Patches 2. Apply Array Firmware Patches 3. Apply Disk Firmware Patches OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: PARTS NOTE: REFERENCE INFORMATION: http://pts-storage.us.oracle.com/products/Maserati/MIRE.html Attachments This solution has no attachment |
||||||||||||
|