Asset ID: |
1-71-1316239.1 |
Update Date: | 2017-07-28 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1316239.1
:
How to Remove and Replace a T3 and T3+ HDD [VCAP]
Related Items |
- Sun Storage T3 Array
- Sun Storage T3 Array for the Enterprise (T3ES)
- Sun Storage T3+ Array
- Sun Storage T300 Array
- Sun Storage T3 Array for the Workgroup (T3WG)
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Storage T3+ Array - Version All Versions to All Versions [Release All Releases]
Sun Storage T3 Array - Version All Versions to All Versions [Release All Releases]
Sun Storage T300 Array - Version All Versions to All Versions [Release All Releases]
Sun Storage T3 Array for the Enterprise (T3ES) - Version All Versions to All Versions [Release All Releases]
Sun Storage T3 Array for the Workgroup (T3WG) - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Remove and Replace a Sun StorEdge T3 Array Hard Disk Drive (HDD)
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
T3 / T3+ product training
TASK COMPLEXITY: 2
TIME ESTIMATE: 60 minutes
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
Hard Disk Drive Replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
This should be a redundant component, dependent on initial array configuration and quantity of simultaneous disk drive faults. A data backup is not a pre-requisite but is a wise precaution.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD precautions.
Follow procedures documented in the respective service documentation listed below. The customer may have to re-register a standalone array with their management software.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
1) verify fru stat output shows new drive as ready enabled.
2) Drive reconstruction from any hot spares will depend on configuration. This is up to the customer to identify and resolve based on the References below.
PARTS NOTE:
REFERENCE INFORMATION:
T3 and T3+ Array Documentation Suite at http://docs.oracle.com/cd/E19699-01/index.html
Attachments
This solution has no attachment