Asset ID: |
1-71-1316192.1 |
Update Date: | 2018-05-23 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1316192.1
:
How to Replace a Sun Fire X4270 M2 Power Supply
Related Items |
- Sun Fire X4270 M2 Server
- Big Data Appliance Hardware
- SPARC SuperCluster T4-4
- SPARC SuperCluster T4-4 Full Rack
- Exadata Database Machine X2-2 Half Rack
- Exadata Database Machine X2-2 Full Rack
- SPARC SuperCluster T4-4 Half Rack
- Exadata Database Machine X2-2 Hardware
- Exadata Database Machine X2-8
- Exadata Database Machine X2-2 Qtr Rack
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Big Data Appliance Hardware - Version Not Applicable to Not Applicable [Release N/A]
Exadata Database Machine X2-2 Qtr Rack - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-2 Half Rack - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-2 Full Rack - Version All Versions to All Versions [Release All Releases]
SPARC SuperCluster T4-4 - Version -Not Applicable- to -Not Applicable- [Release NA]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4270 M2 Power Supply.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 15 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4270 M2 Power Supply needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The following LEDs are lit when a power supply fault is detected:
- Front and rear Service Action Required LEDs
- Rear PS Failure LED on the front of the server
- Failure LED on the faulty power supply
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Caution - *Hazardous voltages are present.*To reduce the risk of electric shock and danger to personal health, follow the instructions.
Remove Power Supply
1. Identify which power supply (0 or 1) requires replacement. A lit Service Action Required LED on a power supply indicates that a failure was detected.
2. Gain access to the rear of the server where the faulty power supply is located.
3. Release the cable management arm (CMA), it is located at the rear of the server rack.
a. Press and hold the CMA release tab.
b. Rotate the cable management arm out of the way so that you can access the power supply.
4. Disconnect the power cord from the faulty power supply.
5. Grasp the power supply handle and press the release latch.
6. Pull the power supply out of the chassis.
Install Power Supply
1. Align the replacement power supply with the empty power supply chassis bay.
2. Slide the power supply into the bay until it is fully seated.
3. Reconnect the power cord to the power supply. Verify that the AC Present LED is lit.
4. Close the CMA, inserting the end of the CMA into the rear left rail bracket.
5. Verify that the following LEDs are extinguished:
- On power supply: Service Action Required LED
- On the front of the chassis: Service Action Required and REAR PS LEDs
- On the rear of the chassis: Service Action Required LED
Note - See Server Back Panel Features for more information about identifying and interpreting system LEDs.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE INFORMATION :
Sun Fire X4270 M2 Server Service Manual http://download.oracle.com/docs/cd/E19245-01/
Attachments