Asset ID: |
1-71-1315642.1 |
Update Date: | 2017-04-05 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1315642.1
:
How to replace a V440 Key Kit:ATR:788:1
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers.
Reason: FRU CAP
Applies to:
Sun Fire V440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to replace a V440 Key Kit
Fix
*DISPATCH INSTRUCTIONS*
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
V440/Netra 440 Product Training
TASK COMPLEXITY: 1
TIME ESTIMATE: 90 minutes
*FIELD ENGINEER INSTRUCTIONS*
PROBLEM OVERVIEW:
Key Broken
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server
2. Replace the door key switch
3. Wear an antistatic band to avoid the electrostatic discharge
4. Remove the front section of the lid assembly
5. Disconnect the wiring harness from the back of the keyswitch assembly
6. Remove the locknut on the back of the keyswitch assembly
7. Remove the keyswitch assembly through the server's front panel
8. Locate the new keyswitch assembly through the server's front panel
9. Tighten the locknut onto the back of the keyswitch
10. Reconnect the wiring harness
Changing all the 4 positions of key and verifying it works
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Followup the start-up procedure as set by sys-admin
REFERENCE INFORMATION:
Sun Fire V440 Server Parts Installation and Removal Guide
http://download.oracle.com/docs/cd/E19088-01/v440.srvr/816-7729-10/816-7729-10.pdf
Attachments